G0028 Purge Tube
Incorporates a 14/20 standard taper joint to fit K0066 or RDE0010 cell tops. A two-way Teflon stopcock directs inert gas stream through the analyte solution for displacement of dissolved oxygen or over solution to form inert gas blanket. Only the flexible Teflon tubing contacts the solution.
- T14/20 Standard Taper Joint
|
|
|
G0300 Porous Glass Frits (Replaces G0100 Vycor Frits)
- Package of 5
- 4 mm diameter
- Includes 5 pieces of Teflon heat shrink tubing for mounting of frits
|
|
|
K0015 Polishing Kit
A kit for polishing graphite or cleaning glassy carbon electrodes. Complete with polishing cloth, 0.5 µm alumina and wash bottle. |
|
|
K0062 Polarographic Cell Bottom
2 mL minimum volume. Working volume of 2 - 50 mL. |
|
|
K0064 Jacketed Cell Bottom
A water jacketed version of the K0060 Cell Bottom suitable for connection to constant temperature circulators. Working volume of 5 - 50 mL.
|
|
|
K0065 Reference Electrode Bridge Tube
Provides isolation of the K0077 or G0093 reference electrode from test solution to prevent contamination of test solution by reference electrode filling solution. Incorporates a Porous Glass frit, making it ideal in situations where leakage of the test solution must be kept to an absolute minimum with minimal electrical resistance. The K0065 comes complete and ready to use immediately. Five replacement Porous Glass frits and five lengths of Teflon heat-shrink tubing are also supplied.
|
|
|
K0085 Polarographic Cell Bottoms
|
|
|
RDE0026 Reference Electrode Bridge Tube
- 14/20 Standard Taper Joint on top
- 28/15 Standard Ball Joint for mounting of tube to cell
- 72 mm from top to top edge of ball joint
- 70.5 mm from bottom of ball joint to tip
- Tip incorporates a 4 mm Porous Glass Frit
- Similar to part GOO95, except lower portion of the tube is shorter in the RDE0026
|
|
|
K0077 Saturated Calomel Reference Electrode
- 3.5" long
- 14/20 Standard Taper Joint
- 4 mm Porous Glass Frit on the End
- Saturated Potassium Chloride Filling Solution
|
|
|
G0093 Mercury-Mercurous Sulfate Reference Electrode
This reference electrode is identical in physical configuration to the K0077 Reference Electrode except the G0093 contains a mercury-mercurous sulfate inner element immersed in a saturated potassium sulfate solution. The electrode is employed in situations in which the use of a saturated calomel electrode would be unsatisfactory, for example, chloride analysis, silver analysis, etc.
- 3.5" long
- 14/20 Standard Taper Joint
- 4 mm Porous Glass Frit on the End
- Saturated Potassium Sulfate Filling Solution
|
|
|
K0103 Non-Aqueous Reference Electrode
Incorporates a T14/20 standard taper joint for use with the K0065 reference electrode bridge tube. Inner element is a silver wire immersed in acetonitrile containing 0.1M AgNO3. This electrode is employed in applications involving non-aqueous supporting electrolytes such as benzene-methanol, acetonitrile and DMF. Incorporates a 4 mm Porous Glass frit at the tip.
|
|
|
G0155 Non-Aqueous Filling Solution
A solution of 0.1M AgNO3 in Acetonitrile for use with the K0103 reference electrode. 125 mL. |
|
|
G0194 Polyethylene Frits and Tubing
- For use in highly alkaline solutions, pH > 10, where Porous Glass frits will dissolve
- Package of 5
- 4 mm diameter
- Includes 5 pieces of Teflon heat shrink tubing for mounting of frits
|
|